A simple concept

Simplifying forensic recovery through a non-contact, non-destructive approach in a single tool that feels familiar and intuitive, just like a DSLR.

See BlindSite in action

Explore how BlindSite performs in real conditions, discover what it can do, and take a closer look at the product from every angle.

BlindSite in any conditions

No need to worry about sunny outdoor crime scenes. BlindSite works in any condition!

2 min

Daylight Challenge

Forensic Fingerprint Detection | BlindSite Field Demo: Vehicle in Bright Daylight

This video was made using BlindSite Scene Multi-evidence.

3 min

Demo video

BlindSite capabilities

Watch what BlindSite is capable of in just 3 minutes

A closer look from every angle

Explore the design, layout, and physical details that make BlindSite intuitive, portable, and ready for use in the field.

Capabilities

Explore the advancements possible with BlindSite

All-Environment Performance

All-Environment Performance

Works in daylight and darkness conditions
Use on porous and non-porous surfaces
Flat, curved, transparent, and illuminated
Capture at an angle or perpendicular to surface (flat, curved, transparent, and illuminated )
Precision & Capture Capability

Precision & Capture Capability

Search up to 10 m, capture from 10 cm
Ignores background information
Safe & Non-Destructive Operation

Safe & Non-Destructive Operation

Non-contact digital scale bar
Safe to use. No chemicals
Advanced Imaging & Intelligence

Advanced Imaging & Intelligence

Secondary scene camera and automated scene still overlay
In-built AFIS for immediate suspect identification supplied by ROC
No connectivity required, secure operation

Tech Bits

Auto Imaging Control

Autofocus and autoexposure

Specialist Detection Modes

Automated modes for fingermarks, blood and semen

High-Resolution Scene Capture

Scene camera: image and video up to 4K

Adjustable Aperture Range

9 aperture stops (f3.5 to f48)

System Integration Ready

Compatible with Case Management System

Built-In Analysis Tools

Image analysis tools: histogram, gain / ISO and inversion

Comprehensive Metadata Logging

Logged and recorded metadata including time and location

Secure Evidence Storage

Evidence saved on dedicated SD card up to 2TB

Integrated AFIS Database

Hosted AFIS database up to 2TB

Lightweight Design

Approx. 2 kg

Compact Form Factor

Dimensions: 23 x 18 x 13 cm

Integrated Touchscreen

Touchscreen size: 7”

Extended Battery Life

Rechargeable battery: 3+ hours non-stop use

Auto Imaging Control

Autofocus and autoexposure

Auto Imaging Control

Autofocus and autoexposure

Auto Imaging Control

Autofocus and autoexposure

Auto Imaging Control

Autofocus and autoexposure

Auto Imaging Control

Autofocus and autoexposure

Auto Imaging Control

Autofocus and autoexposure

Auto Imaging Control

Autofocus and autoexposure

Auto Imaging Control

Autofocus and autoexposure

Auto Imaging Control

Autofocus and autoexposure

Auto Imaging Control

Autofocus and autoexposure

Auto Imaging Control

Autofocus and autoexposure

Auto Imaging Control

Autofocus and autoexposure

Auto Imaging Control

Autofocus and autoexposure

Download the Brochure

Explore BlindSite’s capabilities in more detail

From Our Hands to Yours

A look inside the BlindSite Peli™ Storm Case™

Discover our BlindSite products and which best suits your work

BlindSite Scene Multi-evidence

Suitable for traditional crime scenes, cold cases, covert operations, Intelligence, Surveillance, Reconnaissance or a lab environment 

BlindSite Scene Fingermark Pro

Designed for the most complex and critical applications, including counter terrorism, bombings, and EOD

Frequently Asked Questions

Quick answers to common questions. If you don’t see what you’re looking for, please get in touch.

What is hyperspectral imaging, and how does it differ from multispectral imaging?

Hyperspectral imaging (HSI) is an advanced optical technique used in BlindSite that captures very narrow wavelength bands (typically 1–10 nm), providing enhanced sensitivity. In contrast, multispectral imaging (MSI) uses broader wavelength bands (typically 50–100 nm). This allows HSI cameras, like BlidnSite, to focus on specific peak wavelengths, producing higher-contrast responses and revealing evidence, such as latent fingerprints, that may be invisible to the naked eye.

Are there consumables or accessories required to use BlindSite?

No. BlindSite is a fully integrated solution that does not require ALS, chemicals, powders, or additional consumables or accessories, reducing both time and operational cost.

What is the benefit of a non-contact, non-destructive approach?

A non-contact, non-destructive approach preserves evidence for further analysis. For example, BlindSite can capture a latent fingermark in situ without physical contact, enabling minutiae comparison while preserving the sample for potential DNA analysis, increasing the likelihood of identification.

Can BlindSite detect body fluids that would normally require luminol?

Yes. BlindSite can detect blood traces, including diluted samples. It detects haemoglobin through absorption (similar to luminol) and can also detect blood plasma via fluorescence, which luminol cannot. This increases detection capability and reduces false positives from substances such as bleach, rust, and household cleaners.

Does BlindSite only locate bodily fluids or also analyse them?

BlindSite locates potential bodily fluids and provides a preliminary indication (e.g., blood or semen), but it is not a confirmatory analytical tool. Its purpose is to enable rapid, targeted detection and digital capture in situ prior to collection, supporting investigation context and evidential integrity.